This guide explains how acoustic performance is measured, which systems perform best, and where sound actually leaks in a real office.
The best sound reduction comes from solid 75mm or 100mm partitioning, which achieves ratings of up to 52dB, enough to keep confidential conversations private. Double-glazed frameless glass reaches up to 47dB (Rw), so choosing glass does not mean choosing noise. The most common acoustic failure is not the wall at all: it is the door, or sound travelling over the partition through the ceiling void.
How is sound reduction measured?
Partition acoustic performance is quoted as an Rw rating in decibels: the higher the number, the more sound the partition blocks. These are laboratory figures for the panel itself. As a rule of thumb:
Around 30dB
Normal speech is audible but muffled. Fine for general space division.
35 to 44dB
Speech is heard as a murmur; words are hard to make out. Suits most offices and meeting rooms.
45dB and above
Conversation detail does not carry. The territory for boardrooms, HR, legal, and medical settings.
On-site, the whole assembly determines what you hear: panel, door, junctions, and the routes around the partition.
A high panel rating with weak points elsewhere will not deliver the number on the datasheet.
Why a few decibels make a big difference
Decibels are a logarithmic scale, so the numbers don’t behave like prices or measurements. Every 10dB of extra reduction cuts the sound energy passing through to a tenth, which the ear hears as roughly halving the loudness. A 50dB partition therefore lets through around one-hundredth of the sound energy of a 30dB one, not “20 less”.
It works the other way too: a 2 to 3dB difference between two quoted systems is barely perceptible in a real office, so it is rarely worth paying a premium for on its own. Compare systems in 5 to 10dB steps, and spend the difference on doors and ceiling voids instead, where the gains are real.
Which partitioning offers the best sound reduction?

Solid 75mm and 100mm
Plasterboard on each side of the stud (two layers for 100mm) with an acoustic quilt in the cavity achieves up to 52dB. SoundBloc-grade board pushes performance further.

Double-glazed glass
Frameless double glazing with 10mm or 12mm glass reaches up to 47dB (Rw), and framed systems perform similarly. Single glazing is noticeably weaker, so specify double for confidential rooms.

Budget 50mm panels
Honeycomb-core panels achieve around 29dB: basic separation from our most cost-effective system. Ideal where visual privacy matters more than sound insulation, but not for privacy-critical rooms.

Doors: the weak point
A standard solid-core door achieves roughly 20dB, less than half the rating of a good solid wall. Acoustic door sets with perimeter and drop seals close the gap, and are usually the most cost-effective acoustic upgrade.
Why can I still hear through a soundproof partition?
Because sound rarely goes through a good partition, it goes around it. The usual flanking paths are:
The Ceiling Void
The Door
The Floor
Services Penetrations
On our surveys, we look for all four before recommending a specification, because upgrading the panel while ignoring the flanking paths wastes money.
Sound insulation vs sound absorption: what is the difference?
They solve different problems, and mixing them up leads to disappointing results.

- Sound insulation stops noise passing between rooms.
- Sound absorption reduces noise and echo within a room.
Hard offices with glass, plasterboard & hard floors reflect sound; acoustic wall and ceiling panels absorb it. Acoustic panels will not stop your neighbour from hearing your meeting, and a heavier wall will not fix an echoey room. Busy open-plan areas usually need absorption; confidential rooms need insulation; many offices need both.
We install Class A acoustic absorber panels (such as the Soundtect Prism range, made largely from recycled polyester and itself recyclable) on walls and ceilings, in a wide choice of colours and geometric designs that double as a design feature.
Frequently Asked Questions
Soundproofing & Acoustic Partitioning
For general meeting rooms, aim for an assembly rating of 40dB or better. Our 75mm system reaches up to 43dB (Rw). For boardrooms, HR, or anywhere genuinely confidential, specify 45dB or higher, such as our 100mm system, which reaches up to 52dB. Rw is a laboratory figure for the panel alone, so the door and ceiling void decide the real result.
Yes, within reason. Double-glazed systems reach up to 47dB (Rw) in frameless form with 10mm or 12mm glass, enough to keep conversation details private in normal office conditions. Single glazing is noticeably weaker, so specify double glazing for confidential rooms. If you need the highest performance available, a solid partition still wins.
In most cases, yes. Our solid warehouse partitioning systems reach up to 52dB, and insulating above the suspended ceiling reduces the sound that passes over the top. An acoustic door set with perimeter and drop seals helps keep performance close to the panel rating. See our Warehouse & Factory Offices page.
Often, yes. Adding insulation above the ceiling line and upgrading door seals can noticeably reduce the sound passing between rooms without rebuilding the walls. Sealing gaps around services helps too. Absorber panels also help, but they work differently: they cut echo within a room and improve speech clarity rather than block sound from getting to the next room.
Open-plan noise is mostly echo, so absorption works better than insulation or building solid partitions. Acoustic absorber panels reduce echo and make speech clearer. Where a team or room needs genuine privacy, add partitioning with a higher dB rating for that area.
No. Even a high-performance partition reduces sound rather than eliminating it, and the aim in offices is speech privacy. At 45dB and above, conversation detail doesn’t carry. Reaching that on site depends on the whole assembly: the door, ceiling void, floor line and services, as well as the partitioning panels.